Lincoln Electric IDEALARC R3R-500 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla System spawalniczy Lincoln Electric IDEALARC R3R-500. Lincoln Electric IDEALARC R3R-500 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
SVM139-A
June 1998
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However,
your overall safety can be
increased by proper installation
. . . and thoughtful operation on
your part. DO NOT INSTALL,
OPERATE OR REPAIR THIS
EQUIPMENT WITHOUT READ-
ING THIS MANUAL AND THE
SAFETY PRECAUTIONS CON-
TAINED THROUGHOUT. And,
most importantly, think before
you act and be careful.
SERVICE MANUAL
World’s Leader in Welding and Cutting Products Premier Manufacturer of Industrial Motors
Sales and Service through subsidiaries and Distributors Worldwide
22801 St. Clair Ave. Cleveland, Ohio 44117-1199 U.S.A. Tel. (216) 481-8100
For use with machine code numbers 9534, 9537, 9874 and 9884
IDEALARC
®
R3R-300, -400 and -500
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
View Safety Info View Safety Info View Safety Info View Safety Info
RETURN TO MAIN INDEX
Przeglądanie stron 0
1 2 3 4 5 6 ... 107 108

Podsumowanie treści

Strona 1 - R3R-300, -400 and -500

SVM139-AJune 1998Safety Depends on YouLincoln arc welding and cuttingequipment is designed and builtwith safety in mind. However,your overall safety

Strona 2 - MAGNETIC FIELDS

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 3 - FUMES AND GASES

NOTESG-2 G-2IDEALARC R3RReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master T

Strona 4

G-3ELECTRICAL DIAGRAMSR3RWiring Diagram-R3R-300ELECTRICAL SYMBOLS PER E1537LEGENDD5D6D7POCKET AMPTROL SENSING BRIDGEL1 DC OUTPUT FILTERR1R2R3R41514134

Strona 5 - MATEUR ET À REDRESSEUR

G-4ELECTRICAL DIAGRAMSR3RG-4Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Mast

Strona 6

G-5ELECTRICAL DIAGRAMSR3RWiring Diagram - R3R-400 (Code 9874), R3R-500ELECTRICAL SYMBOLS PER E1537LEGENDD5D6D7POCKET AMPTROL SENSING BRIDGEL1 DC OUTPU

Strona 7 - - INSTALLATION SECTION

G-6ELECTRICAL DIAGRAMSR3RPocket Amptrol Schematic33.2KR38X1141213Q3475R1068.1KR4433.2KR39D933.2KR561W12VDZ1D310050VC468.1KR5115J50VTP133.2KR621W12VDZ2

Strona 8

G-7ELECTRICAL DIAGRAMSR3RSnubber Board Schematic & Layout1 AMP/400 VOLT (UNLESS OTHERWISE SPECIFIED)LM124 (UNLESS OTHERWISE SPECIFIED)COMMON CONNE

Strona 9

G-8ELECTRICAL DIAGRAMSR3RR3R-300 Control PC BoardIDENTIFICATIONPART No.REQÕD.ITEMR80,R81,R82R92,R93,R94R92,R93,R94QU1,QU2,QU3 C1

Strona 10 - INSTALLATION

G-9ELECTRICAL DIAGRAMSR3RR3R-400 Control PC BoardIDENTIFICATIONPART No.REQÕD.ITEMR80,R81,R82R101,R102,R103R92,R93,R94R92,R93,R94QU1,QU2,QU3 R1

Strona 11

G-10ELECTRICAL DIAGRAMSR3RR3R-500 Control PC BoardIDENTIFICATIONPART No.REQÕD.ITEMR80,R81,R82R101,R102,R103R92,R93,R94R92,R93,R94QU1,QU2,QU3 R

Strona 12

Read this entire installation section before youstart installation.SAFETY PRECAUTIONSELECTRIC SHOCK can kill.• Do not touch electrically liveparts or

Strona 13

INPUT CONNECTIONSELECTRIC SHOCK can kill. • Have a qualified electricianinstall and service this equip-ment. • Turn the input power off at thefuse b

Strona 14

Have a qualified electrician connect the input powerleads to the L1, L2, and L3 terminals of the input con-tactor. Follow all national and local elec

Strona 15

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 16 - A-10 A-10

The output (welding) cables are connected to the out-put terminals marked “+” and “-”. See Table A.1 forrecommended cable sizes for the combined leng

Strona 17 - - OPERATION SECTION

NOTESA-10 A-10IDEALARC R3RReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master

Strona 18 - OPERATION

Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOCSection B-1 Section B-1IDEALARC R3RTABLE OF CONTENTS- OPERATION SEC

Strona 19

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 20

GENERAL DESCRIPTIONThe Idealarc R3R is an SCR controlled constant cur-rent DC output power source for welding and cutting.The R3R-300 uses a single ra

Strona 21

Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOCSAFETYi iIDEALARC R3RFOR ENGINEpowered equipment.1.a. Turn the engi

Strona 22

CONTROLS AND SETTINGSAll operator controls and settings are located on thecase front assembly. See Figure B.1 for their loca-tions.FIGURE B.1 – CASE

Strona 23 - - ACCESSORIES SECTION

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 24 - ACCESSORIES

WELDING OPERATIONOPERATING STEPSLOCAL CONTROLThe following procedures are for using the IdealarcR3R in the local (“R3R”) control mode of operation.For

Strona 25 - - MAINTENANCE SECTION

Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOCTABLE OF CONTENTS- ACCESSORIES SECTION -Accessories...

Strona 26 - MAINTENANCE

OPTIONS/ACCESSORIESFACTORY INSTALLED OPTIONSPOLARITY SWITCHPermits changing polarity at the machine output ter-minals.METERSAmmeter and Voltmeter.POCK

Strona 27

Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOCSection D-1 Section D-1IDEALARC R3RTABLE OF CONTENTS- MAINTENANCE S

Strona 28

SAFETY PRECAUTIONSELECTRIC SHOCK can kill.• Only qualified personnelshould perform this mainte-nance.• Turn the input power OFF atthe disconnect swi

Strona 29

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 30 - THEORY OF OPERATION

NOTESD-4 D-4IDEALARC R3RReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master T

Strona 31

Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOCSection E-1 Section E-1IDEALARC R3RTABLE OF CONTENTS- THEORY OF OPE

Strona 32

Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOCSAFETYii iiIDEALARC R3RARC RAYS can burn.4.a. Use a shield with the

Strona 33

GENERAL DESCRIPTIONThe Idealarc R3R welder is a three-phase transformerrectifier type constant current power source designedfor DC manual welding and

Strona 34

OUTPUT RECTIFICATION,CONTROL, AND FEEDBACKThe three-phase AC output from the main transformersecondary is rectified and controlled through the SCR/dio

Strona 35

THEORY OF OPERATIONE-4 E-4IDEALARC R3RReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Retu

Strona 36 - TROUBLESHOOTING & REPAIR

PROTECTIVE DEVICES ANDCIRCUITSTwo thermostats protect the R3R from excessiveoperating temperatures and overload conditions.Excess operating temperatur

Strona 37

SCR OPERATIONA silicon controlled rectifier (SCR) is a three terminaldevice used to control rather large currents to a load.An SCR acts very much like

Strona 38

Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOCSection F-1 Section F-1IDEALARC R3RTABLE OF CONTENTS- TROUBLESHOOTI

Strona 39

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 40

ELECTRIC SHOCK can kill.Have an electrician install and servicethis equipment. Turn the machine OFFbefore working on equipment. Do nottouch electric

Strona 41

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 42

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 43

Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOCSAFETYiii iiiIDEALARC R3RFOR ELECTRICALLYpowered equipment.8.a. Tur

Strona 44

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 45

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 46

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 47

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 48

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 49

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 50

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 51

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 52

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 53

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 54

Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOCSAFETYiv ivIDEALARC R3RPRÉCAUTIONS DE SÛRETÉPour votre propre prote

Strona 55

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 56

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 57

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 58

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 59

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 60

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 61

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 62

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 63

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 64

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 65

MASTER TABLE OF CONTENTS FOR ALL SECTIONSv vIDEALARC R3RPageSafety...

Strona 66

TROUBLESHOOTING & REPAIRF-26 F-26IDEALARC R3RReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Mast

Strona 67

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 68

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 69

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 70

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 71

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 72

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 73

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 74

TROUBLESHOOTING & REPAIRF-34 F-34IDEALARC R3RReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Mast

Strona 75

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 76

Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOCSection A-1 Section A-1IDEALARC R3RTABLE OF CONTENTS- INSTALLATION

Strona 77

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 78

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 79 - TROUBLESHOOTING

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 80

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 81

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 82

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 83

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 84

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 85

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 86

REASSEMBLY13. For reassembly, carefully place the SCR/ diodeassembly into position on the mounting brackets.14. Replace and tighten the four nuts and

Strona 87

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 88

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 89

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 90

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 91

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 92

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 93

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 94

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 95

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 96

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 97

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 98 - F-64 F-64

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 99

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 100 - IDEALARC R3R

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 101 - ELECTRICAL DIAGRAMS

3. Install the bottom primary coils, one on each of thethree legs of the bottom iron assembly. The coilsmust be in correct position (left, center, r

Strona 102

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 103

REASSEMBLING THE MAINTRANSFORMER INTO THE MACHINENOTE: The following procedure assumes you havecompletely reassembled the transformer coilsas describ

Strona 104

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 105 - GENERAL INFORMATION

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 106 - R3R-300 Control PC Board

Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master TOC Return to Master TOC

Strona 107 - R3R-400 Control PC Board

NOTESF-64 F-64IDEALARC R3RReturn to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master

Strona 108

ELECTRICAL DIAGRAMSG-1 G-1Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOCReturn to Master TOC Return to Master

Komentarze do niniejszej Instrukcji

Brak uwag